When hot water is no longer required the appliance pump (or fan)
may continue to operate to dissipate the residual heat within the boiler.
A flow restrictor is fitted within the appliance which limits a hot
water delivery rate to a maximum of:
24CDi 9.0 (±15%) litres/minute
28CDi 10.0 (±15%) litres/minute
35CDi II 12.0 (±15%) litres/minute
Hot Water and Central Heating mode:
When a demand is made for heating by the system controls (i.e. a
programmer or room thermostat), the pump will energise, circulating
primary water around the heating system and the burner will light.
The heat output from the
appliance in this mode has
been factory set to maximum.
The appliance will operate as
necessary to maintain the
temperature of the radiators
at the level set by the
adjustment of the Heating
Temperature Control Knob.
(See Fig. 2.)
If the system no longer
requires output to maintain
the desired room temperature,
the burner will extinguish.
The pump will continue to
run for a short period to
dissipate the residual heat
from the appliance and then
switch off.
The appliance will supply
heat to the central heating
system as required. A demand
for hot water at a tap or
shower will override the
central heating function for
the period of the domestic hot
water demand.
Fig. 1. System Diagram.
Automatic air
vent
Gas to water
heat
exchanger
Circulating
pump
Water to
water heat
exchanger
Diverter valve
CH
flow
Domestic
hot water
out
Domestic
cold
supply
CH
return
Safety
discharge
Pressure
relief valve
Boiler
Expansion
vessel