Worcester 28i Junior Especificaciones

Busca en linea o descarga Especificaciones para Termostatos Worcester 28i Junior. Worcester 28i Junior Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
This booklet is accurate at the date of printing but will be superseded and should be disregarded if specifications and/or appearances are changed in the interests
of continued improvement.
All goods sold are subject to our official Conditions of Sale, a copy of which may be obtained on application.
PUBLICATION 8 716 108 402b 02/07
Worcester, Bosch Group, Cotswold Way, Warndon, Worcester WR4 9SW.
Telephone: (01905) 754624. Fax: (01905) 754619.
Worcester, Bosch is a trading name of BBT Thermotechnology UK Ltd.
Technical Helpline (08705) 266241.
www.worcester-bosch.co.uk
24i / 28i jjuunniioorr
WALL MOUNTED COMBINATION BOILERS FOR CENTRAL HEATING
AND MAINS FED DOMESTIC HOT WATER
INSTALLATION AND
SERVICING INSTRUCTIONS
This appliance is for use with Natural Gas or LPG (Cat II 2H3P TYPE C12 & C32)
24i GC NUMBER 47 311 69 (N.G.) GC NUMBER 47 311 71 (L.P.G.)
28i GC NUMBER 47 311 70 (N.G.) GC NUMBER 47 311 72 (L.P.G.)
GB/IE
APPLIANCE OUTPUTS
Domestic Central
Hot Water Heating
24i 28i
Minimum 7.5 kW 8.0 kW
Maximum 23.5 kW 27.5 kW
IMPORTANT: THESE INSTRUCTIONS MUST BE LEFT WITH THE USER OR AT
THE GAS METER
Read the instructions before starting work - they have been written to
make the installation easier and prevent hold-ups.
Vista de pagina 0
1 2 3 4 5 6 ... 21 22

Indice de contenidos

Pagina 1 - / 28i jjuunniioorr

This booklet is accurate at the date of printing but will be superseded and should be disregarded if specifications and/or appearances are changed in

Pagina 2 - 2. Introduction

Note: This fault-finding information is for guidance only. Worcester Heat Systems cannot be held responsible for costs incurred bypersons not deemed t

Pagina 3

Commence normalcentral heating modeuntil temperaturereaches 20°C34There is a delay of 6 seconds, pump pulses for 2 seconds,60 second wait,2 second pum

Pagina 4

Roomthermostatand/or mainsprogrammer(or link) Onfaciaprogrammer(if fitted) OnCH controlknob On3318. Operational Flow DiagramsMAIN SWITCHONCENTRALHEATI

Pagina 5 - 3. Technical Data

321 - 23-49102812 -1314 -151619201118248527671725-2621-23NOTE: READ THIS SECTION FULLY BEFORE COMMENCING THEINSTALLATION.11.1 GeneralThe appliance is

Pagina 6

1 H05-333 Burner 24 NG 1 8 716 105 484 02 H05-352 Burner 28 NG 1 8 716 105 485 03 H05-337 Gas Valve NG 1 8 716 105 654 04 H05-338 Gas Valve LPG 1 8 71

Pagina 7 - All dimensions in mm

20 Auto Air VentRemove the complete pump assembly as described in Section16.18. Take care not to strain the electrical connections.Pull out the clip s

Pagina 8 - 4. Siting The Appliance

15 Primary [ch] SensorRemove the clip-on facia cover and the cabinet. Lower the faciaonto the support lugs.Carefully pull-off the connections. Release

Pagina 9 - 8. Open Vent System

9 Inlet Water Filter and Flow Restrictor Remove the flow turbine as described in 16.8 preceding.Taking care, remove flow restrictor assembly from the

Pagina 10 - 10. Gas Supply

5 Combustion Chamber Insulation. Remove inner casing door and combustion chamber cover.Slide the damaged insulation panel from the applianceRear Remov

Pagina 11 - Fig. 9. Wiring diagram

2 Spark ElectrodeRemove the inner casing cover and the combustion chamber cover.Carefully pull off the lead from the electrode. Unscrew the screwand r

Pagina 12 - 18. Operational Flow Diagrams

4320. Conversion InstructionsNOMINAL BOILER RATINGS (10 Minutes After Lighting)BOILER ADJUSTED FOR G20 (Natural Gas)OUTPUT INPUT (Net) GAS RA

Pagina 13 - IMPORTANT

IMPORTANT: Turn off the gas supply and electrically isolatethe appliance before replacing any components.NOTE: Turning the control knob fully anti-clo

Pagina 14 - Accessories and Kits

Inner Case Cover Unscrew the two screws and lift off. Refer to Fig. 39.Combustion Chamber Cover Unscrew the two screws, lift andpull forward to remov

Pagina 15

23Fig. 41. Inner case components1. Flue hood 2. Overheat thermostat3. Burner4. Combustion chamber cover5. Spark electrode assembly6. Heat

Pagina 16

42Boiler is running in“Autofrost stat” mode.See Section 17.Replace control board.Note: A damp boardcould cause this fault.Is the boiler in a verycold

Pagina 17

41Replace control board.In the unlikely eventof this not solving theproblem replace codeplug.Pressure switch hasopened duringoperation.Check flue forb

Pagina 18 - 5mm longer than the air duct

40Remove multiwayconnector from boardposition ST16. Testresistance across pins16 and 17 ( yellowwire). Is it between 1kOhm and 30 kOhm?Test resistance

Pagina 19 - Switched Live

39Remove combustionchamber cover.Is the sense electrodeand lead in goodcondition and is gapcorrect?Replace flame sensoror wiring.NoNoRemove multiwayco

Pagina 20 - 16. Replacement Of Parts

38NoNoReset and restart theboiler in CH mode.Does the pump run?Test resistance acrosspins 4 and 5(blue wires). Is resistance between10Ω and 25Ω ?Repai

Pagina 21

37Re-connect the 3-wayconnector and open atap to run the turbine.Is there between 1.5Vand 4.5V across thegreen and blackwires/terminals?Is there conti

Pagina 22 - 14. Hand Over

36Is there a 230V AC livesupply acrossTerminal ST2 pins Land N?Switch off electricalpower.Has fuse F1 blown?Replace fuse andinvestigate cause.Suggesti

Comentarios a estos manuales

Sin comentarios