Worcester Si Mk II Manual de instrucciones Pagina 1

Busca en linea o descarga Manual de instrucciones para Termostatos Worcester Si Mk II. Worcester Si Mk II Instruction manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
DT20RF PROGRAMMER
DIGISTAT - Radio frequency controlled room thermostat
with twin channel digital programmer
FOR GREENSTAR CDi, GREENSTAR i JUNIOR AND GREENSTAR Si MODELS
ALSO GREENSTAR i SYSTEM AND GREENSTAR CDi SYSTEM MODEL
(ONLY WHEN USED WITH THE OPTIONAL INTEGRAL DIVERTER VALVE)
INSTRUCTION MANUAL
OPERATING AND INSTALLATION
UK/IE
8_716_115_495a 9/2/09 11:49 Page 1
Vista de pagina 0
1 2 3 4 5 6 ... 31 32

Indice de contenidos

Pagina 1 - INSTRUCTION MANUAL

DT20RF PROGRAMMERDIGISTAT - Radio frequency controlled room thermostatwith twin channel digital programmerFOR GREENSTAR CDi, GREENSTAR i JUNIOR AND GR

Pagina 2 - INSTRUCTIONS

Changing the Minimum Temperature Setting1. To adjust the “Preset” temperature enter the Usermenu by pressing and holding the Set button formore than 5

Pagina 3

TAMPER PROOFING (All Models)To tamper proof the product i.e. preventunauthorised adjustment of the product, set theMin. and Max. (HI and Lo) temperatu

Pagina 4 - TECHNICAL DATA

Central heatingon lightCentral heating select button, movesthe indicator up and down to selectmode and accepts changesCentral heating advance button:t

Pagina 5

Central heating:1. Press select button tochooseoff = constantly OFFtimed = up to 3 ON & 3 OFF time periods as programonce = ON from first ON

Pagina 6

NOTE:The ON/OFF periods pre-programmed forCentral Heating and Hot Water pre-heat areshown in the table below. These factory installed settings can be

Pagina 7

Setting Central Heating (CH) MON - FRI1. Press set? until SET and PROG? are shown inthe display.2. Press OK to enter program.3. Press OK to select MON

Pagina 8

Setting individual weekdays:NOTE: If you do not require individual weekdaytimes, then press set? until SET SAT-SUNare displayed and continue on the ne

Pagina 9

Setting Central Heating (CH) SAT - SUN:1. Press OK to select weekend.2. Press OK to select CH.NOTE: Speed up the display by holding down the + or - bu

Pagina 10 - ADVANCED SETTING

Setting individual weekend days:NOTE: If you do not require individual weekend day times, then press set? until the normaldisplay is shown.If you do n

Pagina 11 - BATTERY REPLACEMENT

Setting holidays:1. Press the set? button until SET and HDAY aredisplayed.2. Press OK and the display shows 00.3. Press + or - to set the number of da

Pagina 12 - GENERAL INFORMATION

MANUAL INFORMATIONPLEASE READ THESE INSTRUCTIONSCAREFULLY BEFORE STARTINGTHESE INSTRUCTIONS ARE APPLICABLE TOTHE WORCESTER BOSCH MODEL(S) STAT-ED ON T

Pagina 13 - OPERATING CONTROLS

Setting the clock and time1. Press the set? button until SET and CLOCK areshown in the display.2. Press OK to display 24hr and ON.3. Press + to switch

Pagina 14 - PRE-PROGRAMMED SETTINGS

Setting the date:1. Press the set? button until SET and DATE? aredisplayed.2. Press the OK button once, the year flashes onthe display.3. Press + or -

Pagina 15 - PROGRAMMABLE SETTINGS

ClipsCover panelScrewTabBlanking plateTabCover panelClipsScrewProgrammerDANGER: 230 VOLTSDO NOT TOUCH THE ELECTRICALCOMPONENTS OR CIRCUITSCAUTION: ISO

Pagina 16

DIGISTAT / DT20RF RECEIVERSETTING UP THE RF LINKDIGISTATINSTALLATIONReceiver set up:After initial start up, the colon, CH and antenna symbols should b

Pagina 17

DIGISTATINSTALLATIONDIGISTAT / DT20RF RECEIVERSETTING UP THE RF LINK6. Remove the batteries from the Digistat and waitfor the display to fade. 7 Press

Pagina 18

DIGISTATINSTALLATIONDIGISTAT / DT20RF RECEIVERMOUNTING THE DIGISTAT1. Loosen the single screw from the bottom of thetransmitter using a small flat bla

Pagina 19

DIGISTATINSTALLATIONDIGISTAT / DT20RF RECEIVERTO CANCEL SIGNALSTRENGTH MODETo cancel signal strength mode:1. Remove the batteries from the transmitter

Pagina 20

DIGISTATINSTALLATIONDIGISTAT / DT20RF RECEIVERTO CHECK PREVIOUSLYINSTALLED UNIT To check signal strength on previouslyinstalled and paired units :1. P

Pagina 21

DIGISTATINSTALLATIONDIGISTAT / DT20RF RECEIVERTO CHECK PREVIOUSLYINSTALLED UNIT Signal strength indicatorsTransmitter code(may be different)LED indica

Pagina 22 - Programmer

DIGISTATINSTALLATIONDuring normal operationThe LED on the receiver will flash red, approximatelyevery 5 minutes. This denotes that a radio signalis be

Pagina 23 - INSTALLATION

TABLE OF CONTENTSTECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2DIGISTAT ROOM THERMOSTAT . . . . . .

Pagina 24

Maintenance:The Digistat RF Room thermostat requires no maintenance.The outer casing can be wiped clean using a drycloth. DO NOT use polish or deterge

Pagina 25 - MOUNTING THE DIGISTAT

8_716_115_495a 9/2/09 11:49 Page 31

Pagina 26 - STRENGTH MODE

Worcester, Bosch GroupCotswold Way, Warndon, Worcester WR4 9SW.Tel. 01905 754624 Fax. 01905 754619worcester-bosch.co.ukWorcester, Bosch Group is a bra

Pagina 27 - INSTALLED UNIT

EC Directives:European Union Law Directive 2000/84/ECLow Voltage Directive (2006/95/EC)Electro-Magnetic Compatibility Directive (89/336/EEC)EC Marking

Pagina 28

What is a room thermostat?A room thermostat simply switches the heatingsystem on and off as necessary. It works by sens-ing the air temperature, switc

Pagina 29 - NORMAL OPERATION

ADVANCED FEATURESAdjusting the Setpoint using the PresetTemperature ModeChange the temperature at the press of a button,for example, if you are going

Pagina 30 - MAINTENANCE

2. If you want to set a new setpoint, just rotate thedial until your required setpoint is shown on thedisplay. After a couple of seconds the display w

Pagina 31

Changing the Preset Temperature1. To adjust the “Preset” temperature enter theUser menu by pressing and holding the Setbutton for more than 5 but less

Pagina 32 - CONTACT INFORMATION

Changing the Maximum Temperature Setting1. To adjust the “Maximum” temperature enter theUser menu by pressing and holding the Setbutton for more than

Comentarios a estos manuales

Sin comentarios